These devices are designed as Magnetic Scale, Digital Ruler and Digital Gauge. Based on magnetic detection methods for measurement to provide strong resistance to dust, oil, vibration and shock. High precision and high-grade magnetic scale signals allow measurement in the harshest of environments within resolutions of 0,1 µm.

range 15...>2200 mm

precision machine tools

resolution up to 0,1 µm

CNC/NC-lathe and milling machine

accuracy up to 0,1 µm

retrofit for lathe and mills

high precision magnetic principle

X-Y stages and other dedicated machines

output: TTL-signal

cutting and shearing machines

reference point

testing instruments

resistent against dust, oil and vibration

inspection equipment

high reliability

manufacturing machines

 


 

 

 

 

Digital Ruler for Display Units o. Control Systems  Series SJ700/SD608

range

70...2170 mm

output

TTL-signal A/B/Z phase o. position display unit

accuracy

up to +/- 0,005 mm

resolution

up to 0,0005 mm !!!

max. travel speed

1 m/s

operating temperature

0...+40°C

power supply

5 VDC o. supplied by display unit

protection class

IP 54

 


 

 

 

 

Digital Ruler for Machine Control System - Series SR127/128

range

50...2200 mm

output (detector)

TTL-signal, A/B phase output and up/down output for direction, simultaneous output of inverted signals or connection to display unit

accuracy

up to +/- 0,003 mm

resolution

up to 0,0001 mm !!!

max. travel speed

1 m/s

operating temperature

0...+40°C

power supply

supplied by detector or display unit

temperature expansion coefficient

(11+/-1)x10EXP-6 / degree °C

protection class

IP 54

 


 

 

 

 

Miniatur Ruler - Series SR118

range

15...260 mm

output (detector)

TTL-signal, A/B phase output and up/down output for direction, simultaneous output of inverted signals or connection to display unit

accuracy

up to +/- 0,002 mm

resolution

up to 0,001 mm

operating temperature

0...+40°C

power supply

supplied by detector or display unit

temperature expansion coefficient

(11+/-1)x10EXP-6 / degree °C

protection class

not specified

 


 

 

 

 

Open Ruler - Series SR721

reange

150...400 mm

output (detector)

TTL-signal, A/B phase output and up/down output for direction, simultaneous output of inverted signals or connection to display unit

accuracy

up to +/- 0,005 mm

resolution

up to 0,0005 mm

shaft diameter

2 mm

operating temperature

-5...+40°C

power supply

supplied by detector or display unit

temperature expansion coefficient

(11+/-1)x10EXP-6 / degree °C

protection class

not specified

 


 

 

 

 

 

München:
 
Stammsitz

Mehlbeerenstr.4
82024 Taufkirchen
Fon: 089 / 67 97 13 - 0
Fax: 089 / 67 97 13 - 250